- Products
- Detection plate for X-ray machine
Detection plate for X-ray machine
Detachable detection plate for X-rays, Cesium direct deposit technology, "losseless AED" and "Truview Art Technology"
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days
Detection plate for X-ray machine
Dimensions
Model EVS4343: 43 cm (17") x 43 cm (17")
Model EVS2430: 24 cm (10") x 30 cm (12")
Weight
Model EVS4343: 4,5 kg (10 lb)
Model EVS2430: 1,9 kg (
Pixel spacing
Model EVS4343: 140 μm
Model EVS2430: 76 μm
Resolution
Model EVS4343: 3,072 x 3,072
Model EVS2430: 3,072 x 3,840
Input voltage: 12V, 5A
Communication: Giga Ethernet
X-ray, I / F: Lossless AED / Sync trigger
Create values by offering a better view
Join us and move on to modern and effective treatment. Ask for a demonstration.
Exprimer, innovative digital radiography solutions
Image sharpness intensified with CsI deposited directly. Direct deposited CsI can provide clearer images at the lowest dispersion compared to conventional CsI and GOS scintillators. High quality images are not the result of such a characteristic as smaller pixel size or low electronic noise, but achieved when all detector components are optimized to work in harmony with each corresponding specification.
Better DQE performance in higher spatial frequencies Exprimer with its well-oriented direct deposition column CsI + TFT structure has high DQE performance providing exceptional high quality images. It also demonstrates comparatively excellent DQE performance over a high spatial frequency range.
Faster image display with high speed operating speed. Quick image preview and display times of Exprimer products allow more efficient operation leading to increased productivity. Image preview in both wired and wireless modes are achieved in less than 2 seconds and an image is acquired in 4.5 and 6 seconds respectively.
Best image processing solution for optimized quality images. ECONSOLE1 (UI software) and TRUVIEW®ART (image sharpness algorithm) provide a perfect solution to increase diagnostic productivity and accuracy. With a convenient user-friendly interface design and powerful image processing engine, ECONSOLE1 & TRUVIEW®ART enables more accurate diagnosis with high quality and highly defined images.
The Exprimer series
Get excellent X-ray imaging quality with Exprimer:
Excellent image quality using directly deposited CsI
Ultimate Sharpness Image by TRUVIEW® ART
Instant upgrade to digital mobile radiography system
Reducing patient dose with reliable lossless AED
High resistance to shock and vibration
Low cost fixed grid (120 lines / inch)
Lightweight and durable design for portable applications
Exprimer, DRTECH's innovative digital radiography solution combined advanced "information technology" with the very latest digital detection technology. Due to its versatility, Exprimer provides ultimate image quality and can be applied in multiple environments for various applications. EVS 3643 and EVS 2430, Exprimer's two portable models offer unlimited portability with reliable operation. Update now! Experience the unbeatable performance of Express and increase your diagnostic productivity and confidence!
The conventional AED function consists of three stages: X-ray detection, panel reset and load integration. The integration time is delayed because additional time is required for the panel reset which occurs after the panel detects the incoming x-ray signal. Loss is inevitable even when separate sensor modules in the detection system are used. When acquiring images of thick objects, the loss rate may further increase. The lossless AED has innovatively improved the reliability of the sensitivity through the optimization of the operating pattern.
Image quality technology
Improved image quality using advanced reverse filtering technology. The sharpness of the image of an object in a conventional image is reduced due to the scattering of light. "TRUVIEW ART", DRTECH's unique reverse filtering technology, reconstructs and improves image sharpness to increase the possibility of detecting abnormalities including micro calcifications.
Excellent post-processing image quality. With algorithms and parameters optimized for each part of the body, adaptive noise reduction to minimize image signal loss and improve image detail through multi-frequency image processing.
A well thought out conception of user experience. Intelligent workflow minimizing the need for page turns and mouse clicks, an editable toolbar and dual monitor support and easy-to-use stitching (up to 5 images) thanks to the setup wizard image settings. The user can select from nine (9) processed picture styles using different settings on a 7.5cm (3 ") x 7.5cm (3") dot matrix display.
Tablets and smart phone. Supports viewing crystal-clear digital images on display devices with WiFi communication such as smart phones and tablets.
AED sans perte
Réduction de la dose du patient avec une détection et une intégration plus fiables des rayons X. Augmentation de la sensibilité du AED et détection de rayons X stable et très précise. Fonctionnement fiable sans interruption par choc externe ou vibration. La pile est de plus longue durée grâce au système d'exploitation à faible consommation d'énergie. Passage facile du mode veille au mode acquisition avec les changements de mode intelligent.
Mobilité
Technologies innovantes pour portabilité illimitée. Le chargement simultané de deux piles est possible avec le double chargeur de pile. Avec sa conception d'insertion horizontale et verticale, ce chargeur prend en charge à la fois les piles EVS 3643 et EVS 2430 W. Prise en charge de 12 V, la charge en déplacement est possible car il se connecte à la sortie de cigare de n'importe quelle voiture. Le chargeur est inclus avec les détecteurs EVS 3643 et EVS 2430W.
Rapidité
Affichage d'image plus rapide avec un schéma d'exploitation optimisé. L'aperçu rapide de l'image et le temps d'affichage des produits Exprimer permettent un fonctionnement plus efficace conduisant à une productivité accrue. L'aperçu de l'image à la fois en mode filaire et en mode sans fil est atteint en moins de 2 secondes et une l'image est acquise en 4,5 et 6 secondes respectivement.